What's All This "Others Stay Lighted" Stuff, Anyhow?

Bob Pease  |   ED Online ID #14867  |   March 1, 2007


The box of Christmas lights said "If one or more lights go out, others stay lighted." Yeah, sure. My wife bought several cheap boxes of 100-light strings, and they looked very nice. This year, she had great plans to drape them along a fence, which would look real pretty. But some of the strings were dead—kind of frustrating when you want to put the lights up now.

I did some simple checks. If one bulb went open, the others in series went out. Yeah, 5-V double-anode zeners can keep the other lamps running, but that's not what you get when you pay $1.06 for 100 bulbs. As I hadn't planned to do any troubleshooting, I had no tools or meters with me—not even an LED.

To avoid disappointing my wife, I had to get to work and fix them, that night, so she could impress some friends who were coming over. It wasn't a question of having spare bulbs. I had plenty. But I really didn't want to pull out all of the bulbs and test them, as that surely would have done more harm than good.

The bulbs' bases were flaky too, and unplugging and plugging would have ruined them. I didn't even trust the sockets! I finally found some lamp cord from an old lamp, a couple of nails, and some tape for insulation.

TO THE TEST
These 2.5-V bulbs would take a little overvoltage testing. So I pulled out the first and eleventh bulbs and shorted out that group with the wire and nails. I decided there was no lack of continuity. I went on to the group of 11 to 21, 21 to 31, and 31 to 41—still no effect. Oh, what I would have given for an ohmmeter or a voltmeter!

Finally, I shorted out bulbs 41 to 50, and the other 40 bulbs lit up nice and bright! Hooray. As I indicated on page 7 of my book on troubleshooting, "troubleshooting a series divider is sometimes a nice challenge"—yeah, if you can gain access to the resistor string, which wasn't easy in this case. I suppose I could have taken a pin and poked it through the insulation into the wires, but that's not so great.

I checked continuity between 41 and 45 and between 45 and 50, and both were open. I had at least two failures, so I had to be pretty careful making assumptions about binary searching! By this time, some of the bulbs were getting flaky. I set aside some bulbs as "not trusted" and threw out a couple as hopeless.

One bulb refused to light but apparently would pass current. Another bulb seemed burned. And, one bulb had a melted base. But finally I got all the strings working with minimum tools—just a wire and some nails.

I'm going to use a tiny test kit in my future Christmas decorating chores, probably a 4.7k 2-W resistor and/or a 1-µF 200-V capacitor, as well as a couple of insulated alligator clips and safety pins. Meanwhile, trusting cheap foreign junk isn't always a good idea.

I'm not really mad at the bulbs' manufacturer. I just wish it was a little more truthful about the probable failure modes.

CLASSIC LIGHT BULB TRICK
Let's say you have a motorgenerator set (hydro power?) to generate power and send it back into the 60-Hz grid. But you can't just connect your generator, as it's likely to be out of phase. Connecting it could blow a fuse or cause damage. What to do?

Tie the common of your generator to the grid and connect a couple of 120-V incandescent bulbs in series from your output to the grid. Adjust your power input to get your frequency close to 60 Hz, and then bring the phase as close as possible.

When you see the intensity of those two lights drop gradually to zero, you know the frequency is very close and the phase is very small, so you can throw the switch! Of course, this trick is only a little over 110 years old. No fancy phase meter is needed. This trick does the job.

Comments invited! rap@galaxy.nsc.com —or: Mail Stop D2597A, National Semiconductor
P.O. Box 58090, Santa Clara, CA 95052-8090


Reprints   Printer-Friendly  Email this Article  RSS    Font Size   What's This?


  • C Tools Accelerate HDV Development On Xilinx FPGAs
  • A New Design Inflection Point
  • Forecasting Industry Growth For 2009 And Beyond
  • EDA Retools To Exploit Multicore Architectures
  • Design And Verification Move Up In Abstraction
  • EDA Retools To Exploit Multicore Architectures
  • A New Design Inflection Point
  • Design And Verification Move Up In Abstraction
    1) Transportation Guidelines For Lithium Batteries Get Updated
    (1168 views today)
    2) Build A Smart Battery Charger Using A Single-Transistor Circuit
    (261 views today)
    3) WHITE PAPER: Liquid-Level Monitoring Using a Pressure Sensor
    (196 views today)
    4) 1-A Switching Regulators Operate With 96% Efficiency To Replace Linear Regulators
    (128 views today)
    5) The Field Of Energy Harvesting Begins To Ripen
    (109 views today)
    ALL TOP 20



    Reader Comments

    Finding bust bulbs in Christmas lamp strings is a real pain even with a test meter - and I seem to have to do it every year. I had an idea though which should work in england with 240v mains anyway. Just add a little bit of neon to every bulb - that way when the filament breaks the voltage across the bulb goes up from maybe 12 to mains, and the neon should glow. Would be very cheap too..

    regards

    Allan.

    allan Hurst -September 10, 2007

    There was an Idea for Design in November 17, 1997 that addressed this problem, "Circuit-break locator for the holidays" <http://www.elecdesign.com/Articles/Index.cfm?ArticleID=6351> and an update early in '98 that simplified it a lot. A 74HC86 XOR gate (1/4) fed with 2x AA batteries, an LED on the output with a current-limiting resistor (330-ohm or so), and a couple of 1Mohm 1/4W resistors with full length leads on the inputs, spread left and right. Unfortunately, the link to that article has gotten scrambled with an oscillator article. I built one of these gadgets and keep it in the Christmas-light box (with batteries removed, of course) and it works like a champ. The differential E-field around an open bulb in the string brings the LED on immediately. I hope the staff of ED can find the right article to restore it to the archive. 73, WA6DZS

    Phil Barnes-Roberts -April 08, 2007

    I first saw the light bulb "phase meter" trick in a circa 1910 electricians handbook I bought at a yard sale. They included one more step:

    "Have the apprentice throw the switch"

    Guess that way the senior staff would be around in case the phase was not close enough...

    Anonymous -March 06, 2007

    As I vaguely remember one major problem with Edison's wunderkind, DC power transmission, was that coupling DC generators was extremely hard because only small change in output would result in one generator suddenly delivering all the load. AC on the other hand, tended to automagically even out load due to phase shifting.

    Frank Borger -March 02, 2007

    POST YOUR COMMENTS HERE
    Name:

    Email:
    Your Comments:

    Enter the text from the image below


    Please refresh the page if you have trouble reading this text.

    Search Electronic Design
         
      
     
    Email Newsletter
    Sponsored By:
    The Find Power Products monthly newsletter brings you the most important new developments within the world of power design. The newsletter includes exerpts from industry leader Sam Davis's exclusive blog, as well as overviews of the latest new products.

    Enter Email to Subscribe
      
    Web Seminar
    Sponsored By:
    Title: Exploring How Good GUIs Drive Adoption in the Digital Power Management Space
    Speakers: Don Tuite Deepak Savadaatt
    Date: 10/24/07
    Register: 

    Electronic Design Europe Electronic Design China EEPN Power Electronics Auto Electronics Microwaves & RF
    Mobile Dev & Design Schematics Find Power Products Military Electronics EE Events Related Resources