Solid-State Relay Features Load Indicator

Jay Miller  |   ED Online ID #8438  |   August 9, 2004


Several years ago, I designed a remote energy-control system that split a building into sections and wired the overhead space heaters into "zones." As space was an issue and OAC5s (optically isolated output modules) were way too big, each energy control panel controlled the heaters using homemade discrete solid-state relays (SSRs). While the overall design was fine, a problem arose at 3 a.m. one night. It seemed there wasn't any heat in part of one zone. Someone had flipped off the breaker feeding power to that heater. Apparently it's a common mistake when shutting lights off from a breaker panel. As winter progressed, so did the annoying 3 a.m. calls. A solution had to be found.

Out came the breadboard. After several tries, I came up with a load-indicating SSR. The first idea was to have an LED in the load line with six diodes (1N4004s) connected in series-parallel (see part a of the figure). While it worked in the lab, it failed in the real world. The added voltage drop of about 2 V led to erratic behavior of the gas valves. The worst case was during brownout conditions and long control wires (typically 100 to 200 feet). Back to the breadboard.

The second version presented here, which eliminates the unacceptable voltage drop, has worked for over 15 years in hundreds of panels. While my application involved 24-V ac gas valves and relays, this circuit is easily modified to suit your application.

As shown in part b of the figure, there's a red LED and reverse 1N4004 diode in series-parallel between pin 6 of the MOC3011 optotriac driver and the MT2 pin of the 2N6075A power triac. Also, there's a 10-(omega) resistor from the junction of pin 4 of the MOC3011 and gate of the power triac to the MT1 pin of the power triac. This arrangement of components minimizes the voltage drop of the loop to just the on-state voltage of the triac. That's great news, considering space heaters can easily have 100 to 200 feet of control wire!

Obviously, component values will need to be changed to suit your application—perhaps an R-C snubber across the triac, although I've never needed it. Using a zero-crossing optocoupler might also be required. While not a complicated circuit by any means, the minor expense of an LED, diode, and resistor has eliminated those annoying phone calls and gives peace of mind to both my clients and me.


Reprints   Printer-Friendly  Email this Article  RSS    Font Size   What's This?


  • Synopsys Takes The Analog/Mixed-Signal Plunge
  • October 2, 2008
  • Electronic Design Update: October 1, 2008
  • For Checking Software Without Hardware, FPGAs Are The Answer
  • ESL Platform Looks To Solidify Baseband PHY Design Flow
  • September 25, 2008
  • Electronic Design Update: September 24, 2008
  • Tools Take On IC-Package And SiP Design Challenges
    1) Build A Smart Battery Charger Using A Single-Transistor Circuit
    (193 views today)
    2) Efficient DC-To-AC Inverters Charge Equipment Racks
    (87 views today)
    3) Easily Convert Decimal Numbers To Their Binary And BCD Formats
    (86 views today)
    4) Precision DC motor speed controller
    (76 views today)
    5) VIDEO: Under The Hood Of The Tesla Roadster
    (65 views today)
    ALL TOP 20



    Reader Comments

    am i on?.......****!!!

    Anonymous -March 04, 2007

    ha cha cha chang chang

    Anonymous -March 04, 2007

    GOOD THING

    sreenatha kv -February 28, 2007   (Article Rating: )

    have you ssr 1 input 3 output.

    cuong -October 09, 2005

    I have experience of similar problems and for your interest have realised a bi-polar load indicator that can be placed in series with the load and works over the range of .003 to 10 Amps. It is almost the antithesis of an SSR in that it turns current into low level light signals. Opto outputs are also avaiable for connecting directly to a PLC. The same device can also be powered via a Current Trafo. and sensitive to 0.25 Amps without invading the circuit. Its patented in Europe, Canada and the USA, Q. is anyone in this big wide world interested?

    Anonymous -July 18, 2005   (Article Rating: )

    POST YOUR COMMENTS HERE
    Name:

    Email:
    Your Comments:

    Enter the text from the image below


    Please refresh the page if you have trouble reading this text.

    Search Electronic Design
         
      
     
    Email Newsletter
    Sponsored By:
    Electronic Design UPDATE provides readers with late-breaking news, opinions from industry experts, and timely technology stories. It's a unique opportunity to get your product message in front of engineers, engineering managers, and corporate managers while they're reading about critical information online.

    Enter Email to Subscribe
      

    Electronic Design Europe Electronic Design China EEPN Power Electronics Auto Electronics Microwaves & RF
    Mobile Dev & Design Schematics Find Power Products Military Electronics EE Events Related Resources